MODELS
|
|
ANALYZERS |
|
 |
Pipeline Stream Analyzer
- The Pipeline Stream Analyzer (PSA)
is designed to continuously monitor an incoming gas sample for
H2S, CO2, combustibles and/or other toxic gases. The PSA has a
maximum inlet pressure of 1500 psig (4500 psig available).
- Solid state, electrochemical or
infrared sensors available
- Input pressure to 4500 psig with
membrane filter; additional input filtering may be needed
- Suitable for hazardous area including
Class 1, Div 1 or Div 2
- Options include three 5 amp alarm
contracts; isolated 4-20 mA and MODBUS RTU
- Wireless communications options
available
- Security settings allow locking of
critical parameters
|
|
|
CONTROLLERS |
|
|
 |
C1 Protector 8/16 Ch Display
& Alarm Controller
- with Modbus
Master-Slave RS-485 ports;
NRTL certified for Div. 2 potentially hazardous areas and C22.2
No. 152 for LEL combustibles
-
Accepts up to 16 inputs from many sensor
types and signal ranges. Inputs may be analog or Modbus®
Master port retrieves data via RS-485 data highway
-
CSA approved for Div 2 areas without
purge. CE mark
-
8 channel display mode and option boards
allow economical configuration of systems requiring only 8
channels or less
-
Dual Modbus RS-485 serial ports for
simultaneous master / slave operation. Optional phone modem
-
3 alarm levels per channel. Relay
Acknowledge feature allows silencing of external audible
devices during existing alarms
-
Graphic LCD displays trends, bar graphs
and engineering units. Alarm LED’s flash when new and become
steady after acknowledged
-
Standard SPDT common alarm relays for
HORN, HIGH, WARN & FAULT. Optional discrete channel alarm
relays also available
-
Options such as direct sensor inputs,
4-20mA outputs, discrete alarm relays and others are
sup-ported via an I2C expansion bus
-
Cal Mode offers pushbutton zero / span
calibration for direct sensor interface applications.
Authorization Mode allows locking of critical configuration
variables
-
Magnetic keypad available for
non-intrusive operation in potentially hazardous locations
-
NEMA 4X, Explosion-Proof, panel and rack
mount packaging options available
|
|
|
 |
C2 Protector 2-Ch Display Gas
Detection Controller/Monitor
- with serial
interface; NRTL
certified for Div. 2 potentially hazardous areas and C22.2 No.
152 for LEL combustibles
-
Accepts inputs from one or two local or
remote mounted Toxic / LEL sensors or transmitters
-
CSA approved for Div 2 areas without
purge. CE mark
-
3 independent alarm levels per channel.
Relay Acknowledge feature allows silencing of external
audible devices during existing alarm conditions
-
Graphic LCD readout displays monitored
data as bar graphs and engineering units. Alarm LED’s flash
when new and become steady after acknowledged
-
Two standard SPDT common alarm relays are
configurable for HORN, HIGH, WARN or FAULT alarm conditions.
Optional discrete channel alarm relays are also available
-
Options such as Modbus slave RS-485
serial port, 10-BaseT Ethernet, data logging, 4-20mA
outputs, discrete alarm relays and others are also supported
-
Modbus slave RS-485 serial port allows
interface to Modbus master devices such as PC’s, PLC’s and
DCS’s
-
Cal Mode offers pushbutton zero / span
calibration for direct sensor interface applications.
Authorization Mode allows locking of critical configuration
variables
-
Magnetic keypad available for
non-intrusive operation in potentially hazardous locations
-
NEMA 4X and Explosion-Proof wall mount
packaging options available
|
|
|
 |
Potectector HMI
- Visualization and Data Logging
Software for Gas Detection and Monitoring Applications
-
Expandability - 16 to 160 point
monitoring in real time using Windows XP-based personal
computer. Desktop or touch-screen options available
-
Interface to C1 or C2 controller via
RS-485 MODBUS. Multiple RS-485 channels supported, allowing
mixture of home-run and daisy-chained connections for
multiple controllers, including wireless
-
Real-time view of any channel includes
most recent 15 minute and most recent 24 hour trend graph.
24 hour graph supports zoom, pan, displayed values and
auto-range
-
Up to 10 customer-supplied custom plot
screens display sensor location and real-time status
-
Detailed record of alarm, maintenance and
communication events
-
Alarm 2 color options (Red, Orange, Blue)
allows intuitive and rapid recognition of alarm conditions
|
|
|
 |
Rig Protector Area Protection
System
- Portable system designed to
continuously monitor ambient conditions for toxic or combustible
gas hazards
-
Two to sixteen channels of LEL or toxic
monitoring
-
4-20mA and alarm relay outputs standard;
MODBUS slave output available on C1
-
Choice of catalytic bead or SmartIR
infrared sensors for LEL
-
Thirty minute trend (C2) or 24 hour trend
(C1) history data
-
Optional Class 1 / Divison 2 rated
connectors for hazardous area monitoring
|
|
|
MONITORS |
|
|
 |
GASMAX II Single/Dual Channel
Gas Monitor
- Delivers the latest in gas
detection technology. CSA certified for Class 1 Div 1 & 2;
Values, bargraph and trend data on highly visible LCD. MODBUS
and 4-20mA outputs available. Smart Sensor interface.
-
Toxic/O2, LEL, & dual Toxic/O2 LEL
models. LEL channel may accept 4-20mA input with special
configuration.
-
“Plug In Smart Sensors” store Cal data,
sensor type, range and many other variables. New, or
recently calibrated sensor is automatically recognized by
the GASMAX/II.
-
CSA certified for Explosion Proof
installations
-
Our USB Interface and software allows
configuration of “Smart Sensors” via personal computer.
-
Clock / Calendar time & date stamps
calibrations and alarm trips for later recall to the LCD.
-
Large graphic LCD displays Value, Units,
User Info, Bar-graph and 30-minute trend.
-
Front panel flashing alarm LED indicators
are standard equipment.
-
Simple magnetic wand allows one man
sensor calibration in hazardous areas without area
declassification.
-
Output transmits 1.5mA In Cal signal
during calibrations and 2mA during FAULT conditions.
-
Power-Up & Post Cal delay modes lock
output at 4mA until sensor stabilizes; preventing false
alarm trips.
-
Security mode allows locking of critical
parameters.
-
Options include 5 amp HIGH - WARN - FAULT
alarm contacts with RS-485 modbus or isolated outputs.
|
|
|
 |
GASMAX/EC Two-Wire Gas
Monitor
- Loop-powered monitor shows values,
bargraph and trend data for toxic or oxygen sensors. Flashing
alarm LEDs for Alarm1, Alarm 2 and Fault. Smart Sensor
interface.
-
2-Wire 4-20mA Loop Powered.
-
4-20mA transmits 3mA "In Cal" signal
during calibrations and 2mA during FAULT conditions.
-
“Plug In Smart Sensors” store Cal data,
sensor type, range and many other variables. New, or
recently calibrated sensor is automatically recognized by
the GASMAX.
-
Clock / Calendar time & date stamps
calibrations and alarm trips for later recall to the LCD.
-
Our USB Interface and software allows
configuration of “Smart Sensors” via personal computer.
-
CSA certified for Intrinsically Safe and
Explosion Proof installations.
-
Front panel flashing alarm LED indicators
are standard equipment.
-
Large graphic LCD displays Value, Units,
User Info, Bar-graph and 30-minute trend.
-
Front panel alarm LED indicators are
standard equipment.
-
Allows one man sensor calibration in
hazardous areas without area declassification.
-
Requires only a simple magnetic wand. No
other special electronic devices are needed.
-
"Power-Up" & "Post Cal" Delay Modes lock
output at 4mA to allow sensor stabilization and prevent
erroneous alarm trips.
|
|
|
 |
M1 Gas Monitor
-
Toxic / Oxygen & Combustibles Gas
Detection. CSA C22.2 No. 152 approved
-
Allows non-intrusive "one-man" sensor
calibration in hazardous areas without area
declassification.
-
Requires only a simple magnetic wand. No
other special electronic devices are needed.
-
CSA certified for Div. 1 & 2 Groups B, C,
D hazardous areas AND C22.2 No. 152 for LEL Combustible
Monitors.
-
"END OF SENSOR LIFE" feature warns when
sensors are nearing time for replacement. Offset & gain
calibration values may be seen on the LCD for tracking
sensor degradation with age.
-
Provides continuous digital readout of
the engineering units monitored by the sensor.
-
Universal sensor head accepts "plug-in"
sensor modules allowing field replacement of sensors without
wiring changes.
-
4-20mA output sends constant 1.5mA "In
Cal" signal during calibration periods.
-
1 minute "Power-Up" & "Post Cal" Delay
Modes lock 4-20mA output at 4mA to allow sensor
stabilization and prevent erroneous alarm trips.
-
Standard "Fault Supervision" circuitry
continuously monitors for failed sensor or missing sensor.
4-20mA output transmits 0mA during Faults.
-
Standard M1 models include the M1/LEL for
catalytic bead LEL sensors, the M1/EC for electrochemical
sensors and the M1/mA for 4-20mA inputs.
-
Available options include isolated 4-20mA
output, 5 amp form "C" HIGH - WARN - FAULT alarm contacts
and RS-485 Modbus® interface.
|
|
|
 |
GASMAX II + SMART IR Gas
Monitor
-
GASMAX II with new Smart IR sensor
delivers advanced infrared combustible gas detection at lower
total cost of ownership. Smart Sensor interface.
-
Low total cost of ownership
-
MTBF 5 years
-
CSA Certified for Explosion Proof
installations
-
Large graphic display shows value, units,
30-minute trend
-
Non-intrusive “one person” calibration in
hazardous area
-
Power-up and post-cal delay eliminates
false alarms
-
Options include 5A alarm contacts and
MODBUS out
-
Security settings allow locking of
critical parameters
|
|
|
 |
GASMAX II PID Gas Monitor
-
GASMAX II PID Gas Monitor with Photoionization Detector for
Volatile Organic Compounds (VOC)
Low sensitivity to changes in atmospheric
conditions
Sensor refurbishment option extends life
of PID sensor
Dual channel mode allows simultaneous
monitoring of O2 or toxic gas
“Plug In Smart Sensors” store Cal data,
sensor type, range and many other variables. New, or
recently calibrated sensor is automatically recognized by
the GASMAX/II.
CSA certified for Explosion Proof
installations
Optional USB Interface and software
allows configuration of “Smart Sensors” via personal
computer.
Clock / Calendar time & date stamps
calibrations and alarm trips for later recall to the LCD.
Large graphic LCD displays Value, Units,
User Info, Bar-graph and 30-minute trend.
Front panel flashing alarm LED indicators
are standard equipment.
Simple magnetic wand allows one man
sensor calibration in hazardous areas without area
declassification.
Output transmits 1.5mA In Cal signal
during calibrations and 2mA during FAULT conditions.
Power-Up & Post Cal delay modes lock
output at 4mA until sensor stabilizes; preventing false
alarm trips.
Security mode allows locking of critical
parameters.
Options include 5 amp HIGH - WARN - FAULT
alarm contacts with RS-485 modbus or isolated outputs.
|
|
|
 |
GASMAX ECx Wireless Gas
Monitor
-
Battery-powered wireless gas monitor for oxygen or toxic gas
applications. Shows value in engineering units, 30 minute trend
and flashing LED alarms. Smart Sensor interface.
-
Designed for Hazardous Areas (NRTL
certification pending)
-
One year continuous use on internal
D-cell lithium battery
-
Large graphic display shows value, units,
30-minute trend
-
Built-in 900Mhz license-free wireless
radio modem
-
Flashing LEDs indicate A1,
-
A2, Fault, In-Cal, RF Rx & Tx
-
Signal strength indication helps ensure
reliable link
-
Plug-in Smart Sensors store calibration &
history data
-
Range up to 3000ft, or to 20 miles with
high-gain antenna
-
Power-up and post-cal delay eliminates
false alarms
-
See GASMAX II or IIx for local relays,
backlit display & more
|
|
|
 |
GASMAX IIx Wireless Single
/ Dual Channel Gas Monitor
-
Single or dual channel wireless gas detector. Values, bargraph
and trend data on highly visible LCD. 4-20mA outputs available.
Smart Sensor interface
-
Designed for hazardous areas (NRTL
certification pending)
-
Built-in 900Mhz license-free wireless
radio modem
-
Plug-in Smart Sensors store calibration &
history data
-
Signal strength indication helps ensure
reliable link
-
Simultaneous monitoring of both toxic /
O2 and LEL levels
-
Range up to 3000ft, or to 20 miles with
high-gain antenna
-
Large graphic display shows value, units,
30-minute trend
-
Security settings allow locking of
critical parameters
|
|
|
 |
USB Smart Sensor / Monitor
Interface
-
Program Smart Sensors, Educators and GASMAX monitors with this
USB-based interface. Requires PC running Microsoft Windows XP
-
Allows use of our proprietary Windows®
software to configure GASMAX Transmitter database menus.
Saves time over entering data with magnetic wand.
-
Databases may be saved on PC as .sen
files for repeat use.
-
Download files from USB Interface to one
of 3 devices:
-
Smart Sensor, Educator, or directly to
GASMAX Transmitter.
-
GASMAX Transmitter uploads data from
Smart Sensor, Educator or directly from USB Interface.
-
Educator stores 6 different databases and
is portable for carrying to locations of already installed
GASMAX Transmitters.
-
GASMAX LCD indicates database selected by
the rotary switch.
|
|
|
SENSORS |
|
|
 |
GDS-48 Universal Remote
Sensor
-
New: Remote Sensor for Catalytic Bead, Smart IR or Toxic / Oxyge.
Retrofit superior infrared sensor technology into existing
catalytic-bead installations!
-
Replace existing catalytic-bead LEL
sensors with Smart IR Infrared - no wiring changes!
-
Remote mount catalytic bead LEL sensors
at distances in excess of 1000 ft
-
Remote mount electrochemical toxic or
oxygen sensors at distances of 25 ft - For greater
distances, see the GDS-49 Remote Sensor Transmitter
-
Field-replaceable catalytic bead LEL,
infrared & electrochemical sensors modules
-
Standard stainless steel sensor housing;
aluminum housing available for corrosive environments
-
Easy interface to GASMAX / EC, GASMAX II
monitors and C1 and C2 Protector series controllers
|
|
|
 |
GDS-49 Sensor Transmitter
-
Two-wire Toxic / Oxygen sensor transmitter converts low level
electrochemical sensor output into industry standard 4-20mA
current loop
-
Field replaceable toxic / oxygen sensor
module.
-
Range & target gas configured on sensor
module.
-
Improves system noise immunity because
low level sensor signals are protected within the metallic
sensor head.
-
Industry standard 4-20mA signal may be
transmitted thousands of feet or 2-wires.
-
CSA certified for Division 1 & 2
hazardous areas. May be installed as an intrinsically safe
device with a barrier, or, explosion-proof for NEMA 7
installations.
-
Easily interfaced to GDS Corp. 1, 2, 8,
or 16 channel receiver / display / alarm products.
-
2-wire 4-20mA signal is nonpolar with
protective "steering diode" interface.
-
Standard "Fault Supervision" circuitry
continuously monitors for failed or missing sensor. 4-20mA
output transmits <2mA during failures.
|
|
|
 |
GDS-IR Infrared Point Gas
Detector
-
Dual wavelength design uses infrared radiation to reliably
detect combustible gases
-
No routine calibrations required
-
CSA C22.2 No. 152 Performance certified
-
No regular maintenance
-
Fault indications for all failure states
-
Extremely low cost of ownership
-
Oxygen not required to detect combustible
gases
-
3-wire electrical interface offers easy
retrofit into existing catalytic detector installations
-
Incorporates the highly reliable dual
wavelength concept based on infrared radiation passing
through a volume of gas
-
Fail safe operation of vital functions
continue even when transmission is severely reduced by dirt
on the optics
-
Optional GASMAX/II offers alarm relays,
Modbus® RS-485 or isolated 4-20mA
|
|
|
 |
SharpEye Triple-IR Optical
Flame Detector
-
Self-contained, triple spectrum flame detector uses advanced
detectors and microprocessor-based decision making to reduce
false alarms
-
Triple Spectrum Design
-
Sensitivity Selection
-
User Programmable Configuration
-
Highly Immune to False Alarms
-
Automatic and Manual Built-In Test (BIT)
-
Standard 4-wire Connection
-
4-20mA sink or source (3-4 wires)
configuration
-
RS-485 Interface
-
MTBF Minimum 100,000 Hours
-
3-Year Warranty
-
FM, CSA, ATEX, Gost R & Gost K Approved
-
Hydrogen Model 20/20H also available
|
|
|
ACCESSORIES |
|
|
 |
GDS-51A Loop Isolator
-
Designed to eliminate problems often encountered when
terminating current loops
-
Provides continuous 1500 volt CMV
isolation between input and output current loops
-
Provides an isolated current analog
output capable of driving 20mA through a 750 W load
-
Derives all operating power from the
input current loop
-
Contributes less than 1.75 volts of
additional loop voltage drop
-
Requires no calibration
-
High density DIN rail mount enclosure is
less than 1 inch wide
|
|
|
 |
GDS-54 Loop-Powered Indicator
-
Adds local calibrated engineering-units display to any 4-20mA
current loop circuit
-
Operating power derived from 4-20mA
current loop
-
Square root extract option available
(GDS-54SR)
-
2.5 volt max voltage drop on standard
unit; 5 volt with square root option
-
Large .6 inch tall 4.5 digit LCD readout
-
Selectable decimal points and polarity
sign indicator
-
2 ranges of ZERO & SPAN adjustment allow
calibration in engineering units
-
3˝ active digits plus a selectable "DUMMY
0" least significant digit provide 4˝ digits of display
-
Panel Mount, Explosion Proof, NEMA 4X or
PCB packaging is available
|
|
|
 |
GDS-55 Loop-Powered Alarm
-
Designed to initiate an alarm relay contact closure when the
4-20mA loop current goes above or below a given value
-
Operating power derived from the input
current loop.
-
Fail Safe S.P.D.T. Form C, 2 amp max dry
contacts.
-
Multi-turn alarm set-point adjustment
calibrated by setting millivolt value to correspond to
desired alarm trip point.
-
Alarm may be configured to trip on
increasing or decreasing signals via DIP switch.
-
Latching or auto-reset action set by DIP
switch.
-
3 values of dead-band available via DIP
switch.
-
Contributes less than 7.5 volts of
additional loop voltage drop.
-
L.E.D. visual alarm condition indicator.
-
High density DIN rail mount enclosure is
less than 1 inch wide. Also available in NEMA 4X and NEMA 7.
|
|
|
 |
GDS-56 Loop-Powered Indicator
with Totalizer
-
New: Loop-Powered Indicator with linearization, flashing LEDs
for A1, A2 and Fault. GDS-56T adds 10-digit totalizer function.
Non-intrusive calibration and setup with magnetic wand
-
Easily adds a large sophisticated graphic
LCD readout to any 4-20mA loop. Readout includes E-units,
bar-graph & trend
-
Operating power is derived from the
4-20mA current loop. Only 4.0 volts consumed from the loop
-
ST-54T Totalizer option available to
display up to 10-digit totals
-
Linearizer table allows entry of
square-root and custom curves
-
Magnetic keypad allows non-intrusive
operator interface
-
Alarm 1, Alarm 2 & FAIL alarm level
adjustable trip points flash LED's during alarm conditions
-
Real Time Clock & Calendar time & date
stamps alarm events
-
User defined range, resolution, decimal
points, E-units & tag ID
-
NRTL certified Explosion-Proof NEMA 4/7
enclosure. Alternate packaging is available
|
|